4.AO_841_CI_Etude comparative des mesures dentaires linéaires sur des modèles numériques issus du scanner intra-oral et du CBCT au modèle en plâtre.
DOI :
https://doi.org/10.55715/jaim.v18i4.1026Résumé
Objective: to compare the accuracy of linear dental measurements on digital models generated by intraoral scanning and CBCT, using conventional plaster models as the reference.
Materials and Methods: We conducted a comparative and retrospective study in a private orthodontic dental practice in Abidjan. The study included patients with complete records comprising digital models generated by intraoral scanning, CBCT, and conventional plaster models. Exclusion criteria were models with agenesis or missing teeth, as well as teeth with interproximal restorations. Two software programs were used to perform the various dental measurements (mesiodistal and buccolingual diameters), with the level of statistical significance set at p < 0.05.
Results: A total of 3,600 linear dental measurements were recorded on 1,200 teeth. The mean differences in mesiodistal linear measurements were −1.85 mm for CBCT models compared with plaster models and −1.77 mm for STL models compared with plaster models. These differences were statistically significant (p < 5%). In contrast, the mean differences in vestibulolingual linear measurements were −0.58 mm (CBCT vs. plaster) and −0.68 mm (STL vs. plaster), with no statistically significant differences. Bland–Altman analysis confirmed good agreement in the precision of vestibulolingual linear measurements between CBCT and STL models when referenced to plaster models.
Conclusion: The study demonstrated good agreement in vestibulolingual linear measurements between CBCT and STL models when referenced to plaster models. However, mesiodistal linear measurements differed statistically among the different models. The observed differences highlight the value of combining these techniques alongside the continued development of digital tools
Téléchargements
Références
Virginie Lor. L’évolution squelettique et dentaire de l’appareil manducateur. Sciences du Vivant [q-bio]. 2021. dumas-03588328.
Typhaine Koeppel. Analyse cinématique de l’appareil manducateur humain : constitution d’une base de données de sujets asymptomatiques et comparaison avec sujets à dysfonction. Mécanique des matériaux [physics.class-ph]. Université de Lorraine, 2017.
Nisa A, Erol K, Gokmen K. Comparison of dental measurements between conventional plaster models, digital models obtained by impression scanning and plaster model scanning. Int Orthod. 2019 Mar;17(1):151-158. DOI: 10.1016/j.ortho.2019.01.014
Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop 2009;136:16.e1-4.
Jabri MA, Wu S, Pan Y, Wang L. An overview on the veracity of intraoral digital scanning system and utilization of iTero scanner for analyzing orthodontic study models both In-Vivo and Ex-Vivo. Niger J Clin Pract. 2021 Jan;24(1):1-7. doi: 10.4103/njcp.njcp_698_19. PMID: 33473018.
Jiménez-Gayosso SI, Lara-Carrillo E, López-González S, et al. Difference between manual and digital measurements of dental arches of orthodontic patients. Medicine (Baltimore). 2018;97(22):e10887.
Serrano-Velasco D, Martín-Vacas A, Giovannini G, Paz-Cortés MM, Aragoneses JM. Accuracy Analysis of Digital Models from Intraoral Scanners and 3D-Printed Casts in Children and Teenagers. Children (Basel). 2024 Sep 3;11(9):1082. doi: 10.3390/children11091082.
Frąckiewicz W, Jankowska A, Machoy ME. CBCT and modern intraoral scanners as tools for developing comprehensive, interdisciplinary treatment plans. Adv Clin Exp Med. 2024;33(11):1267–1276.
Carneiro ALE, Reis INR, Bitencourt FV, Salgado DMRA, Costa C, Spin-Neto R. Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis. Dentomaxillofac Radiol. 2024 Apr 29;53(4):207-221.
Pesce, P.; Nicolini, P.; Caponio, V.C.A.; Zecca, P.A.; Canullo, L.; Isola, G.; Baldi, D.; De Angelis, N.; Menini, M. Accuracy of Full-Arch Intraoral Scans Versus Conventional Impression: A Systematic Review with a Meta-Analysis and a Proposal to Standardise the Analysis of the Accuracy. J. Clin. Med. 2025, 14, 71.
Kendall, M. G., and B. Babington Smith. “Randomness and Random Sampling Numbers.” Journal of the Royal Statistical Society 101, no. 1 (1938): 147–66. https://doi.org/10.2307/2980655.
Freund, Y. Concordance entre deux méthodes de mesure d’une même variable : diagramme de Bland et Altman. Ann. Fr. Med. Urgence 6, 143–146 (2016). https://doi.org/10.1007/s13341-016-0621-4
Naidu D, Freer TJ. Validity, reliability, and reproducibility of the iOC intraoral scanner: a comparison of tooth widths and Bolton ratios. Am J Orthod Dentofacial Orthop 2013; 144:304-312.
Park JM, Kim RJY, Lee KW. Comparison of digital models obtained by cone-beam computed tomography and intraoral scanning for dental measurements. Journal of Prosthetic Dentistry. 2016;115(3):325–332
Kim SY, Lim SH, Gang SN, Kim HJ. Accuracy of dental measurements on cone-beam computed tomography and digital dental models. Clinical Oral Investigations. 2017;21(3):939–946
Bolton WA. Disharmony in tooth size and its relation to the analysis and treatment of malocclusion. Angle Orthodontist. 1958;28(3):113–130.
Leifert MF, Leifert MM, Efstratiadis SS and al. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop 2009 ; 136, 16 : 11-14.
Petrović V, Šlaj M, Buljan M, Čivljak T, Zulijani A, Perić B. Comparison of Tooth Size Measurements in Orthodontics Using Conventional and 3D Digital Study Models. J Clin Med. 2024 Jan 26;13(3):730. doi: 10.3390/jcm13030730. PMID: 38337424; PMCID: PMC10856778.
Vazquez, L.; Buser, R.; Carrel, J.-P. Mesiodistal Measurements for Dental Implant Planning: A Prospective Clinical Study of Linear Measurements on Cone-Beam Computed Tomography Images in Comparison with Caliper-Based Measurements on Plaster Casts. Dent. J. 2022, 10, 169. https://doi.org/10.3390/dj10090169
Démétrios J. Halazonetis. Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment. Am J Orthod Dentofacial Orthop (2012): A1-A44, e65-e74, 393-524.
Téléchargements
Publiée
Comment citer
Numéro
Rubrique
Licence
Formulaire droit d’auteur et de propriété du Journal Africain d’Imagerie Médicale
Je certifie / nous certifions que j'ai / nous avons suffisamment participé au contenu intellectuel, à la conception et design du travail, ou à l'analyse et à l'interprétation des données, ainsi qu'à la rédaction du manuscrit, pour en assumer publiquement la responsabilité ; et accepté que mon / notre nom figure sur la liste des auteurs dans l’ordre ci-dessous précisé. Je crois / nous croyons que le manuscrit représente un travail scientifiquement valide. Ni ce manuscrit, ni aucune partie substantielle de ce manuscrit n’a été publié ou envisage d’être publié ailleurs.
Je certifie / nous certifions que les résultats de ce manuscrit relèvent de nos propres données collectées au cours de l'étude. Nous attestons que, si les éditeurs le demandent, nous fournirons les données / informations ou coopérerons sans réserve pour obtenir et fournir les données / informations sur lesquelles le manuscrit est basé, pour examen par les éditeurs ou leurs mandataires. Les intérêts financiers, directs ou indirects, qui existent ou pourraient être perçus comme tels par un ou les auteurs en relation avec le contenu de cet article ont été divulgués dans la déclaration d’intérêt, de même que les sources éventuelles de financement du projet.
Par la présente, je transfère / nous transférons tous les droits de propriété exclusivement au Journal Africain d’Imagerie Médicale du moment que l’article est publié par ce Journal. Le journal aura: le droit d'accorder la permission de republier l'article en totalité ou en partie, avec ou sans frais; le droit de produire des pré-impressions ou des réimpressions et de les traduire dans des langues autres, pour les vendre ou les distribuer librement; et le droit de republier l'article dans une collection d'articles sous tout autre format.
Nous donnons le droit à l’auteur correspondant d’apporter les modifications nécessaires à la demande de la revue, faisons notre la correspondance entre lui et la rédaction pour le compte de ce manuscrit, il agira en tant que garant du manuscrit pour nous.
Je certifie / nous certifions que toutes les personnes ayant apporté une contribution substantielle au travail sans être des auteurs, sont nommées dans les remerciements avec leur permission.