8.AO_928_RDC_Impact de l’installation d’un scanner sur la pratique médicale dans la ville de Kisangani
DOI :
https://doi.org/10.55715/jaim.v18i4.1030Résumé
Introduction: Medical imaging is a cornerstone of modern diagnosis, and computed tomography (CT) has become a major diagnostic tool in contemporary medicine. In the Democratic Republic of Congo, access to advanced medical imaging, particularly CT scanning, remains limited, especially outside the capital. The installation of a CT scanner at the University Clinics of Kisangani in 2024 represented a major step forward for the Tshopo Province and surrounding regions.
Objective: To describe the initial experience related to the installation of the CT scanner in Tshopo Province and to assess its contribution to improving medical practice, while identifying the main technical challenges encountered.
Methods: This was a descriptive, cross-sectional, and retrospective study conducted from June 2024 to December 2025. The parameters analyzed included the volume of examinations performed, patient characteristics, clinical indications, types of CT scans performed, the results and the impact on medical practice.
Results: A total of 158 CT examinations were performed. CT scanning was more frequently requested in male patients (67.7%), and the 45–64 years age group was the most represented (34.1%). Brain CT scans were predominant, accounting for 104 cases (65.8%), followed by 17 spine CT scans (10.7%), 17 abdominopelvic CT scans (10.7%), 11 thoraco-abdomino-pelvic CT scans (6.9%), and other types of CT scans representing 9 cases (5.6%).
CT scanning significantly improved diagnostic accuracy, particularly in the assessment of cranioencephalic trauma and stroke. Some technical constraints were identified, notably unstable power supply and the absence of a specialized biomedical engineer.
Conclusion: The initial experience with the implementation of the first CT scanner in Tshopo Province highlights a significant diagnostic contribution, marked by improved diagnostic accuracy. However, its sustainability remains challenged by technical constraints. A systemic and integrated approach could ensure the sustainability of the CT scanner and preserve its positive impact on improving healthcare delivery.
RÉSUME
Introduction : L’imagerie médicale constitue un pilier fondamental du diagnostic moderne et la tomodensitométrie constitue un outil diagnostique majeur dans la médecine moderne. En République Démocratique du Congo, l’accès à l’imagerie médicale avancée notamment aux examens de scanner demeure limité, particulièrement en dehors de la capitale. L’installation d’un scanner aux Cliniques Universitaires de Kisangani en 2024 a représenté une avancée importante pour la province de la Tshopo et ses environs.
Objectif : Décrire l’expérience initiale liée à l’installation du scanner dans la province de la Tshopo et évaluer son apport dans l’amélioration de la pratique médicale, tout en identifiant les principales contraintes techniques rencontrées.
Méthodes : Il s’est agi d’une étude descriptive, transversale et rétrospective, couvrant la période de juin 2024 à décembre 2025. Ont été étudiés le volume d’examens réalisés, le profil des patients, les indications cliniques, les types d’examens de scanner réalisés, les résultats et l’impact sur la pratique médicale.
Résultats : Un total de 158 examens tomodensitométriques avaient été réalisé. Cet examen était plus demandé chez les malades de sexe masculin à 67,7 % et la tranche d’âge de 45 à 64 ans était la plus représentée à 34,1 %. Les scanners cérébraux étaient prédominants à 104 cas soit 65,8 %, suivies de 17 cas de scanner du rachis (10,7%), 17 cas de scanner abdomino-pelvien (10,7%), 11 cas de scanner thoraco-abdomino-pelvien (6,9%) et d’autres types de scanner représentant 9 cas soit 5,6 %.
Le scanner a permis d’améliorer significativement la précision diagnostique, en particulier dans l’évaluation des traumatismes cranio-encéphaliques et des accidents vasculaires cérébraux. Certaines contraintes techniques, notamment l’instabilité de l’alimentation électrique et l’absence d’un ingénieur biomédical spécialisé sur site, ont été observées.
Conclusion : L’expérience initiale de mise en service du premier scanner dans la province de la Tshopo met en évidence un apport diagnostique significatif, marqué par une amélioration de la précision diagnostique. Cependant sa durabilité reste compromise par des contraintes techniques. Une approche systémique et intégrée peut garantir la pérennité du scanner et préserver son impact positif sur l’amélioration de l’offre de soins.
Téléchargements
Références
Brady AP. Measuring the value of diagnostic imaging. European Radiology. 2021 ;31 :6064–6072.
Smith-Bindman R, et al. Trends in use of medical imaging. JAMA. 2023 ;329(5) :403–415.
World Health Organization. Global strategy on digital health and medical imaging 2020–2025. Geneva ; 2023.
International Atomic Energy Agency. Diagnostic imaging: a critical component of universal health coverage. Vienna ; 2022.
Kabongo JM, et al. Access to computed tomography in Sub-Saharan Africa. Pan Afr Med J. 2021 ;39 :215.
Ministère de la Santé Publique, Hygiène et Prévention, Secrétariat Général, Bulletin SNSAP n° 50 Trim 4 2022
Adejoh T, Ogbole G. CT in low-resource settings. African Journal of Radiology. 2022 ;29(2) :89–96.
Goldstein LN, Dawadi S, Viljoen IM. CT Utilization in a Level One Trauma Center in South Africa. Cureus. 2022 ;14(9) : e29041. doi :10.7759/cureus.29041.
Toungara H. Apport du scanner dans le diagnostic des pathologies non traumatiques du thorax dans le Service de Radiologie et d’Imagerie Médicale du CHU Gabriel Touré [mémoire]. Bamako : Université de Bamako ; 2014.
Camara M, Cissé I, Koné AC, et al. Concordance diagnostique clinique–imagerie–chirurgie dans les urgences abdomino-pelviennes à l’hôpital de Sikasso. J Afr Imag Méd. 2021 ;13(4) :287-293.
Aderinto N, Olatunji D, Abdulbasit M, Edun M. The essential role of neuroimaging in diagnosing and managing cerebrovascular disease in Africa: a review. Acta Neurol Scand. 2023 ;148(6) :621–630. doi :10.1080/07853890.2023.2251490.
Ohaegbulam SC, Mezue WC, Ndubuisi CA, et al. Cranial computed tomography scan findings in head trauma patients in Enugu, Nigeria. Surg Neurol Int. 2011 ;2 :182. doi :10.4103/2152-7806.91137.
Hissene Mahamat T, Issoufou Hamma O, Bako Daouda I, et al. Aspects cliniques et scanographiques des traumatismes crânio-encéphalique à l’hôpital national de Niamey. Health Sci Dis. 2022 ;23(10). doi :10.5281/hsd.v23i10.3945
Diarra L, Agaly H, Cissé BS, et al. CT Findings of Spinal Injuries of Traditional Gold Miners in Mali. Health Research in Africa. 2024
Yao BL, Sanogo SC, Soro M, et al. Aspects scanographiques des traumatismes du rachis à Bouaké. Health Research in Africa. 2025 ;3(1) :68-72. doi :10.5281/hra.v3i1.6312.
Kouakou BDM, Goua JJ, Koffi YT, et al. Diagnostic tomodensitométrique de la hernie discale sur vertèbres de transition lombosacrées à Bouaké : une étude de 128 patients. Health Research in Africa. 2025 ;4(1) :152-157. doi :10.5281/zenodo.17981289.
Nkouonlack C, Wah P, Nkoke C, et al. Clinical spectrum and outcome of non-traumatic spinal cord injury in a resource-limited Sub-Saharan African setting. Health Research in Africa. 2025 ;3(10) :93-101. doi :10.5281/hra.v3i10.7039.
Camara M, Camara T, Diawara Y, et al. Place du scanner dans la prise en charge des métastases cérébrales au Centre Hospitalier Mère et Enfant « Le Luxembourg ». Health Sci Dis. 2021 ;22(4). doi :10.5281/hsd.v22i4.2629.
World Bank Group. Strengthening diagnostic services in LMICs. Washington DC ; 2024.
Traore D, Coulibaly CA, Camara BD, et al. Evaluation of preventive maintenance of medical imaging equipment in five public hospitals of Bamako (Mali) in 2025 : a cross sectional study. Health Sci Dis. 2025 ;26(11). doi :10.5281/hsd.v26i11.7099
Bart Plange A, Bour B, Geletu A, et al. Availability and functionality of diagnostic imaging equipment for road traffic crash injury management in Ghana : Case of Ashanti Region [preprint]. Preprints.org ; 2025. doi :10.20944/preprints202502.1605.v1.
Téléchargements
Publiée
Comment citer
Numéro
Rubrique
Licence
Formulaire droit d’auteur et de propriété du Journal Africain d’Imagerie Médicale
Je certifie / nous certifions que j'ai / nous avons suffisamment participé au contenu intellectuel, à la conception et design du travail, ou à l'analyse et à l'interprétation des données, ainsi qu'à la rédaction du manuscrit, pour en assumer publiquement la responsabilité ; et accepté que mon / notre nom figure sur la liste des auteurs dans l’ordre ci-dessous précisé. Je crois / nous croyons que le manuscrit représente un travail scientifiquement valide. Ni ce manuscrit, ni aucune partie substantielle de ce manuscrit n’a été publié ou envisage d’être publié ailleurs.
Je certifie / nous certifions que les résultats de ce manuscrit relèvent de nos propres données collectées au cours de l'étude. Nous attestons que, si les éditeurs le demandent, nous fournirons les données / informations ou coopérerons sans réserve pour obtenir et fournir les données / informations sur lesquelles le manuscrit est basé, pour examen par les éditeurs ou leurs mandataires. Les intérêts financiers, directs ou indirects, qui existent ou pourraient être perçus comme tels par un ou les auteurs en relation avec le contenu de cet article ont été divulgués dans la déclaration d’intérêt, de même que les sources éventuelles de financement du projet.
Par la présente, je transfère / nous transférons tous les droits de propriété exclusivement au Journal Africain d’Imagerie Médicale du moment que l’article est publié par ce Journal. Le journal aura: le droit d'accorder la permission de republier l'article en totalité ou en partie, avec ou sans frais; le droit de produire des pré-impressions ou des réimpressions et de les traduire dans des langues autres, pour les vendre ou les distribuer librement; et le droit de republier l'article dans une collection d'articles sous tout autre format.
Nous donnons le droit à l’auteur correspondant d’apporter les modifications nécessaires à la demande de la revue, faisons notre la correspondance entre lui et la rédaction pour le compte de ce manuscrit, il agira en tant que garant du manuscrit pour nous.
Je certifie / nous certifions que toutes les personnes ayant apporté une contribution substantielle au travail sans être des auteurs, sont nommées dans les remerciements avec leur permission.